6. Self-Diagnosis Function

28LD5200E (PW1L)

6. Self-Diagnosis Function

Signal circuit check mode: It indicates the check result on some points of the signal circuit and the history of them with On-Screen Display (OSD).

 Signal circuit self-diagnosis function Signal circuit self-diagnosis function

This function is for the failure of the signal circuit, for example the phenomenon as below: "Sometimes power turns off abnormally." "Sometimes picture disappears abnormally." To enter to this Self-Diagnosis mode, follow the next steps:

Preparation:

1)The Power Cord should be connected to AC line and the Main Power switch should be turned on.

2)Turn the power off by the SUB-POWER(Manual background) button of the monitor or the remote control.

Procedure:

1)Press the SUB-POWER(Manual background) button and Manual background button on the bottom of the monitor at the same time, and keep it for more than 5 seconds after the power turned on.

2)The monitor will be turned on, and it will display On-Screen Display of the Self-check result and the failure history as below.

3)Any operation would cancel the Self -Diagnosis mode.

4)The following table shows the OSD symbols and contents of failure PWB in which failure most probably would be allocated according to the number of blinks.

Check item

Check result

[OSD]

 

 

 

Self Check

H11: OK

H15: OK

H16: OK

H31: OK

H32: OK

H33: OK

F63 F63 - - - - - - - - -

Manual backgroundLatest error code

Self check result area

Failure history area

Code

stored up in

Self checking

Problem

Phenomenon

Cause

 

failure history

item

 

 

 

C10(*

 

 

 

 

 

 

No sync. (Snow noise)

OSD of “ ! Check Antenna ”

No connection of ANT cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

appears.

Preset tuning is not yet

H11(*

 

 

 

 

 

 

Tuner problem

Cannot receive the main

Communication error of U101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signal from antenna

 

H15

 

 

 

 

 

 

Composite video SW IC

Cannot receive picture and

Communication error of I201

 

 

 

 

 

 

 

 

 

 

 

 

 

problem

audio

 

 

 

 

 

 

 

 

 

Cannot change input mode

 

H16

 

 

 

 

 

 

Component video SW IC

No component picture

Communication error of I202

 

 

 

 

 

 

 

 

 

 

 

 

 

problem

Cannot change input mode

 

H31

 

 

 

 

 

 

Color demodulator IC

Abnormal color

Communication error of I501

 

 

 

 

 

 

 

 

 

 

 

 

 

problem

Dark picture

 

H32

 

 

 

 

 

 

Sync. separator IC

Unsynchronized picture

Communication error of I601

 

 

 

 

 

 

 

 

 

 

 

 

 

problem

 

 

H33

 

 

 

 

 

 

3D Y/C separator IC

Abnormal color

Communication error of I302

 

 

 

 

 

 

 

 

 

 

 

 

 

problem

Dark picture / No picture

 

H71(*

 

 

 

 

 

 

T/Text IC problem

No T/Text

Communication error of IT01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No picture

 

H72(*

 

 

 

 

 

 

Sound MPX IC problem

No sound from antenna

Communication error of IN01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cannot change MPX

 

 

 

 

 

 

 

 

 

sound

 

F63

 

 

 

 

 

 

I2C-bus latch problem

Cannot store setting data

SCL3/SDA3 latched up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Ex. Channel, Volume etc.)

 

*) This code is no meaning for the models except 32/42PD5000TA because those are without tuner circuit.

If you clear history of failure, make FACTORY RESET: enter the factory setting mode; press the SUB-POWER(Manual background) button, INPUT SELECT(Manual background) button and Manual background button on the bottom of the monitor at the same time. And keep it for more than 5 seconds after the power turned on.