Service

5

11 4

12 5a

Part No. 238402 Spray Gun shown

11 4 7

 

 

 

7

10

 

 

 

 

 

 

 

14

11

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

26

 

13

12

 

 

 

 

 

 

25

8

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

23

C

 

 

 

 

 

 

 

 

A

6

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10b 12

 

 

 

 

 

 

 

 

 

10a 12

 

 

 

10

4

 

 

 

 

 

17

2

 

 

 

 

 

13

 

 

 

5

 

9

 

 

 

 

3

15

15

18

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

2

SERVICE NOTES:

1Gasket (18) must be replaced if diffuser-seat (15) is removed or replaced to avoid fluid leakage

2Gasket (17) must be replaced if fluid connector (30) is removed or replaced to avoid fluid leakage

3Lubricate threads

4Apply anaerobic pipe sealant to threads

5Apply high strength sealant to threads

6Thread nut to bottom thread of needle

FLUID

10Torque to 20±24 ft-lb (27±32 NSm)

11Torque to 15±19 ft-lb (20±26 NSm)

12Lubricate with light-weight oil

13Do not lubricate

7

Use tool (34) to pull needle cartridge until it bottoms in gun

body front end insert.

 

8

U-cup lips face inward

14

If the gun has the AA RAC assembly, tighten the air cap

retaining ring until it bottoms out, while holding the orange tip guard in the desired direction.

9

Torque to 23±27 ft-lb (31±37 NSm)

 

Fig. 8

15 Torque to 90±100 in-lb (10.2±11.2 NSm).

05989

308640 17

Page 17
Image 17
Hitachi 308640 manual 10b 10a, AIR Service Notes