Troubleshooting

Regarding the indicator lamps

When operation of the LAMP, TEMP and POWER indicators differs from usual, check and cope with it according to the following table.

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

 

 

 

 

Lighting

Turned

Turned

The projector is in a standby state.

In Orange

off

off

Please refer to the section “Power on/off”.

Blinking

Turned

Turned

The projector is warming up.

In Green

off

off

Please wait.

Lighting

Turned

Turned

The projector is in an on state.

In Green

off

off

Ordinary operations may be performed.

Blinking

Turned

Turned

The projector is cooling down.

In Orange

off

off

Please wait.

 

 

 

The projector is cooling down. A certain error

Blinking

(discre-

(discre-

has been detected.

In Red

tionary)

tionary)

Please wait until POWER indicator finishes blinking,

and then perform the proper measure using the item

 

 

 

 

 

 

descriptions below.

 

 

 

The lamp does not light, and there is a possibility

 

 

 

that interior portion has become heated.

 

 

 

Please turn the power off, and allow the projector to

Blinking

 

 

cool down at least 20 minutes. After the projector has

In Red

Lighting

Turned

sufficiently cooled down, please make confirmation of

or

the following items, and then turn the power on again.

In Red

off

Lighting

• Is there blockage of the air passage aperture?

 

 

In Red

 

 

• Is the air filter dirty?

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

If the same indication is displayed after the remedy,

 

 

 

please change the lamp referring to the section “Lamp”.

 

 

 

The lamp cover has not been properly fixed.

Blinking

 

 

Please turn the power off, and allow the projector to

 

 

cool down at least 45 minutes. After the projector has

In Red

 

Turned

Blinking

sufficiently cooled down, please make confirmation of

or

In Red

off

the attachment state of the lamp cover. After performing

Lighting

 

 

any needed maintenance, turn the power on again.

In Red

 

 

 

 

If the same indication is displayed after the remedy,

 

 

 

 

 

 

please contact your dealer or service company.

 

 

 

The cooling fan is not operating.

Blinking

 

 

Please turn the power off, and allow the projector to

 

 

cool down at least 20 minutes. After the projector has

In Red

Turned

 

Blinking

sufficiently cooled down, please make confirmation

or

off

In Red

that no foreign matter has become caught in the fan,

Lighting

 

 

etc., and then turn the power on again.

In Red

 

 

 

 

If the same indication is displayed after the remedy,

 

 

 

 

 

 

please contact your dealer or service company.

(Continued on next page) 60

Page 60
Image 60
Hitachi 8916 user manual Regarding the indicator lamps

8916 specifications

Hitachi has long been recognized for its commitment to innovation and excellence in the field of industrial and communication technologies. One of their noteworthy products is the Hitachi 8916,8755H, a sophisticated and versatile piece of equipment designed for a variety of applications.

The Hitachi 8916,8755H is equipped with state-of-the-art features that enhance its performance and usability. One of its main characteristics is its robust processing power, which is driven by an advanced microcontroller that allows for efficient data processing and management. This capability ensures that the device can handle complex tasks with ease, making it suitable for demanding industrial environments.

In terms of connectivity, the Hitachi 8916,8755H incorporates a wide range of communication protocols. This flexibility allows it to seamlessly integrate with existing systems and networks, facilitating smooth data exchange and operational efficiency. Additionally, the device supports both wired and wireless communication, catering to diverse operational needs and environments.

One of the standout technologies of the Hitachi 8916,8755H is its intelligent monitoring and diagnostics system. This feature provides real-time insights into the status of the equipment, enabling users to proactively address issues before they escalate. The system’s predictive maintenance capabilities ensure that the device operates at peak performance, thereby extending its lifespan and reducing downtime.

Another significant characteristic of the Hitachi 8916,8755H is its user-friendly interface. The device is designed with an intuitive display and navigation system, making it accessible even for those with limited technical expertise. This focus on user experience simplifies the operation and configuration of the device, allowing teams to maximize productivity.

Safety is also paramount in the design of the Hitachi 8916,8755H. The device complies with international safety standards, incorporating features that protect both the equipment and its operators. Enhanced security measures safeguard sensitive data, ensuring that information remains confidential and tamper-proof.

In summary, the Hitachi 8916,8755H stands out for its powerful processing capabilities, versatile connectivity options, intelligent monitoring system, user-friendly interface, and robust safety features. This combination of attributes positions it as an ideal solution for a wide array of industrial and communication applications, making it a valuable asset for organizations seeking reliability and efficiency in their operations.