Troubleshooting

Regarding the indicator lamps (continued)

POWER LAMP TEMP indicator indicator indicator

Description

 

 

 

There is a possibility that the interior portion

 

 

 

has become heated.

Blinking

 

 

Please turn the power off, and allow the projector to cool down at least

 

 

20 minutes. After the projector has sufficiently cooled down, please make

In Red

 

 

Turned

Lighting

confirmation of the following items, and then turn the power on again.

or

off

In Red

• Is there blockage of the air passage aperture?

Lighting

 

 

• Is the air filter dirty?

In Red

 

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

 

 

 

If the same indication is displayed after the remedy, please set FAN

 

 

 

SPEED of SERVICE item in OPTION menu to HIGH (43).

 

 

 

It is time to clean the air filter.

 

 

 

Please immediately turn the power off, and clean or change

Lighting

Simultaneous

the air filter referring to the section “Cleaning and replacing

In Green

blinking in Red

the air filter”. After cleaning or changing the air filter, please

 

 

 

be sure to reset the filter timer.

 

 

 

After the remedy, reset the power to ON.

 

 

 

There is a possibility that the interior portion

Lighting

Alternative

has become overcooled.

Please use the unit within the usage temperature

In Green

blinking in Red

parameters (5°C to 35°C).

 

 

 

 

 

 

After the treatment, reset the power to ON.

NOTE • When the interior portion has become overheated, for safety purposes, the projector is automatically shut down, and the indicator lamps may also be turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again.

Shutting the projector down

Shutdown switch

Only when the projector can not be turned off by usual procedure (14) , please push the shutdown switch using a pin or similar, and disconnect the power plug from the power outlet. Before turning it on again, wait at least 10 minutes to make the projector cool down enough.

Resetting all settings

When it is hard to correct some wrong settings, the FACTORY RESET function of SERVICE item in OPTION menu (44) can reset all settings(except LANGUAGE, FILTER TIME, LAMP TIME, FILTER MESSAGE settings and etc.) to the factory default.

61

Page 61
Image 61
Hitachi 8916 user manual Shutting the projector down, Resetting all settings

8916 specifications

Hitachi has long been recognized for its commitment to innovation and excellence in the field of industrial and communication technologies. One of their noteworthy products is the Hitachi 8916,8755H, a sophisticated and versatile piece of equipment designed for a variety of applications.

The Hitachi 8916,8755H is equipped with state-of-the-art features that enhance its performance and usability. One of its main characteristics is its robust processing power, which is driven by an advanced microcontroller that allows for efficient data processing and management. This capability ensures that the device can handle complex tasks with ease, making it suitable for demanding industrial environments.

In terms of connectivity, the Hitachi 8916,8755H incorporates a wide range of communication protocols. This flexibility allows it to seamlessly integrate with existing systems and networks, facilitating smooth data exchange and operational efficiency. Additionally, the device supports both wired and wireless communication, catering to diverse operational needs and environments.

One of the standout technologies of the Hitachi 8916,8755H is its intelligent monitoring and diagnostics system. This feature provides real-time insights into the status of the equipment, enabling users to proactively address issues before they escalate. The system’s predictive maintenance capabilities ensure that the device operates at peak performance, thereby extending its lifespan and reducing downtime.

Another significant characteristic of the Hitachi 8916,8755H is its user-friendly interface. The device is designed with an intuitive display and navigation system, making it accessible even for those with limited technical expertise. This focus on user experience simplifies the operation and configuration of the device, allowing teams to maximize productivity.

Safety is also paramount in the design of the Hitachi 8916,8755H. The device complies with international safety standards, incorporating features that protect both the equipment and its operators. Enhanced security measures safeguard sensitive data, ensuring that information remains confidential and tamper-proof.

In summary, the Hitachi 8916,8755H stands out for its powerful processing capabilities, versatile connectivity options, intelligent monitoring system, user-friendly interface, and robust safety features. This combination of attributes positions it as an ideal solution for a wide array of industrial and communication applications, making it a valuable asset for organizations seeking reliability and efficiency in their operations.