C

Installation

D

A C B TJ

P

KEY

AAir Line Filter

BAir Line Lubricator

C* Bleed±type Master Air Valve

DPump Air Regulator E* Fluid Drain Valve F Fluid Shutoff Valve G Fluid Filter

H* Grounded Fluid Hose J Pump

K Air Line

L Air Pressure Regulator M Pump Fluid Inlet

N In±line Fluid Filter

P Pattern Adjustment Valve Knob Q Fluid Pressure Regulator

R Pressure Gauge S Trigger Safety

T Pump Runaway Valve V* Ground Wire

W Gun Fluid Connector X Air Shutoff Valve

V

QL

RS

F

W

XN

G K

E

H

M

*Equipment required for safe operation of the system. Must be purchased separately.

Fig. 1

Typical Installation

The typical installation shown in Fig. 1 is only a guide for selecting and installing air-assisted airless spray systems. It is not an actual system design. Contact your Graco distributor for assistance in designing a system to meet your needs.

The Graco fluid pump Model 217±523 is designed for use in high pressure air-assisted airless systems. It has a maximum working pressure of 950 psi (66 bar). See instruction manual 307±595 for information on this pump.

Ventilate the Spray Booth

WARNING

TOXIC FLUID HAZARD

To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth.

Never operate the spray gun unless ventilation fans are operating.

Check and follow all of the National, State and Local codes regarding air exhaust velocity require- ments.

4￿3￿￿￿￿￿￿

Page 4
Image 4
Hitachi AA 2000 dimensions Typical Installation, Ventilate the Spray Booth