C
Installation
D
A C B TJ
P
KEY
AAir Line Filter
BAir Line Lubricator
C* Bleed±type Master Air Valve
DPump Air Regulator E* Fluid Drain Valve F Fluid Shutoff Valve G Fluid Filter
H* Grounded Fluid Hose J Pump
K Air Line
L Air Pressure Regulator M Pump Fluid Inlet
N In±line Fluid Filter
P Pattern Adjustment Valve Knob Q Fluid Pressure Regulator
R Pressure Gauge S Trigger Safety
T Pump Runaway Valve V* Ground Wire
W Gun Fluid Connector X Air Shutoff Valve
V
QL
RS
F
W
XN
G K
E
H
M
*Equipment required for safe operation of the system. Must be purchased separately.
Fig. 1
Typical Installation
The typical installation shown in Fig. 1 is only a guide for selecting and installing
The Graco fluid pump Model 217±523 is designed for use in high pressure
Ventilate the Spray Booth
WARNING
TOXIC FLUID HAZARD
To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth.
Never operate the spray gun unless ventilation fans are operating.
Check and follow all of the National, State and Local codes regarding air exhaust velocity require- ments.
43