Hitachi CH 78EC3 (ST) manual Operating Procedures, Fuel Fig, Fueling WARNING Fig, Starting

Models: CH 78EC3 (ST) CH 62EA3 (ST)/CH 66EB3 (ST) CH 50EA3 (ST)/CH 55EB3 (ST)

1 16
Download 16 pages 17.79 Kb
Page 6
Image 6
OPERATING PROCEDURES

OPERATING PROCEDURES

Fuel (Fig. 1)

WARNING

The hedge trimmer is equipped with a two- stroke engine. Always run the engine on fuel, mixed with oil.

Provide good ventilation, when fueling or handling fuel.

Fuel

○ Always use branded 89 octane unleaded gasoline.

○ Use genuine two-cycle oil or use a mix between 25:1 to 50:1, please consult the oil bottle for the ratio or Hitachi dealer.

○ If genuine oil is not available, use an anti-oxidant added quality oil expressly labeled for air-cooled 2-cycle engine use (JASO FC GRADE OIL or ISO EGC GRADE). Do not use BIA or TCW (2-stroke water-cooling type) mixed oil.

○ Never use multi-grade oil (10W/30) or waste oil.

○ Always mix fuel and oil in a separate clean container.

Fig. 1

Always start by filling half the amount of fuel, which is to be used. Then add the whole amount of oil. Mix (shake) the fuel mixture. Add the remaining amount of fuel.

Mix (shake) the fuel-mix thoroughly before filling the fuel tank.

Fueling

WARNING (Fig. 2)

○ Always shut off the engine before refueling.

○ Slowly open the fuel tank (1), when filling up with fuel, so that possible over-pressure disappears.

○ Tighten the fuel cap carefully, after fueling.

○ Always move the unit at least 3 m from the fueling area before starting.

1

Fig. 2

Before fueling, clean the tank cap area carefully, to ensure that no dirt falls into the tank. Make sure that the fuel is well mixed by shaking the container, before fueling.

Starting

CAUTION

Before starting, make sure the cutting attachment does not touch anything.

1. Set ignition switch (2) to ON position (A). (Fig. 3)

* Push priming bulb (4) several times so that fuel flows through the bulb or return pipe. (If so equipped) (Fig. 4)

2

3

A

Fig. 3

4

Fig. 4

2.With the throttle trigger lockout (3) pressed, pull throttle trigger, then slowly release throttle the trigger first, then the throttle trigger lockout. This will lock the throttle in starting position. (Fig. 3)

3.Set choke lever (5) to CLOSED position (B). (Fig. 5)

Fuel (Fig. 1)B C

5Fuel

Fig. 5

4.Pull recoil starter briskly, taking care to keep the handle in your grasp and not allowing it to snap back. (Fig. 6)

6

000Book_CH50EA3_ENG.indb 6

2009/12/21 17:35:38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 6