RS-232C Communication / Network command table (continued)

Names

Operation Type

 

Header

 

 

 

Command Data

 

 

CRC

Action

Type

Setting code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR TEMP

 

Get

BE EF

 

03

 

06 00

BC F4

02 00

B7 30

00 00

 

Increment

BE EF

 

03

 

06 00

DA F4

04 00

B7 30

00 00

OFFSET B

 

 

 

 

Decrement

BE EF

 

03

 

06 00

0B F5

05 00

B7 30

00 00

 

 

 

 

COLOR TEMP

 

 

 

 

 

 

 

 

 

 

 

 

OFFSET B

 

Execute

BE EF

 

03

 

06 00

C8

C5

06 00

4C 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

COLOR

 

Get

BE EF

 

03

 

06 00

B5 72

02 00

02 22

00 00

 

Increment

BE EF

 

03

 

06 00

D3 72

04 00

02 22

00 00

 

 

Decrement

BE EF

 

03

 

06 00

02

73

05 00

02 22

00 00

COLOR Reset

 

Execute

BE EF

 

03

 

06 00

80 D0

06 00

0A 70

00 00

TINT

 

Get

BE EF

 

03

 

06 00

49

73

02 00

03 22

00 00

 

Increment

BE EF

 

03

 

06 00

2F 73

04 00

03 22

00 00

 

 

Decrement

BE EF

 

03

 

06 00

FE 72

05 00

03 22

00 00

TINT Reset

 

Execute

BE EF

 

03

 

06 00

7C

D1

06 00

0B 70

00 00

SHARPNESS

 

Get

BE EF

 

03

 

06 00

F1 72

02 00

01 22

00 00

 

Increment

BE EF

 

03

 

06 00

97

72

04 00

01 22

00 00

 

 

Decrement

BE EF

 

03

 

06 00

46

73

05 00

01 22

00 00

SHARPNESS

 

Execute

BE EF

 

03

 

06 00

C4

D0

06 00

09 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACTIVE IRIS

Set

OFF

BE EF

 

03

 

06 00

0B 22

01 00

04 33

00 00

 

THEATER

BE EF

 

03

 

06 00

CB 2F

01 00

04 33

10 00

 

 

PRESENTATION

BE EF

 

03

 

06 00

5B

2E

01 00

04 33

11 00

 

 

Get

BE EF

 

03

 

06 00

38

22

02 00

04 33

00 00

 

 

1

BE EF

 

03

 

06 00

0E

D7

01 00

14 20

00 00

MY MEMORY

Set

2

BE EF

 

03

 

06 00

9E

D6

01 00

14 20

01 00

Load

3

BE EF

 

03

 

06 00

6E

D6

01 00

14 20

02 00

 

 

 

 

 

4

BE EF

 

03

 

06 00

FE

D7

01 00

14 20

03 00

 

 

1

BE EF

 

03

 

06 00

F2 D6

01 00

15 20

00 00

MY MEMORY

Set

2

BE EF

 

03

 

06 00

62 D7

01 00

15 20

01 00

Save

3

BE EF

 

03

 

06 00

92 D7

01 00

15 20

02 00

 

 

 

 

 

4

BE EF

 

03

 

06 00

02 D6

01 00

15 20

03 00

 

 

4:3

BE EF

 

03

 

06 00

9E

D0

01 00

08 20

00 00

 

 

16:9

BE EF

 

03

 

06 00

0E

D1

01 00

08 20

01 00

ASPECT

Set

NATIVE

BE EF

 

03

 

06 00

5E

D7

01 00

08 20

08 00

14:9

BE EF

 

03

 

06 00

CE D6

01 00

08 20

09 00

 

 

 

 

 

16:10

BE EF

 

03

 

06 00

3E

D6

01 00

08 20

0A 00

 

 

NORMAL

BE EF

 

03

 

06 00

5E DD

01 00

08 20

10 00

 

 

Get

BE EF

 

03

 

06 00

AD D0

02 00

08 20

00 00

OVER SCAN

 

Get

BE EF

 

03

 

06 00

91

70

02 00

09 22

00 00

 

Increment

BE EF

 

03

 

06 00

F7 70

04 00

09 22

00 00

 

 

Decrement

BE EF

 

03

 

06 00

26

71

05 00

09 22

00 00

OVER SCAN

 

Execute

BE EF

 

03

 

06 00

EC D9

06 00

27 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V POSITION

 

Get

BE EF

 

03

 

06 00

0D 83

02 00

00 21

00 00

 

Increment

BE EF

 

03

 

06 00

6B 83

04 00

00 21

00 00

 

 

Decrement

BE EF

 

03

 

06 00

BA 82

05 00

00 21

00 00

V POSITION

 

Execute

BE EF

 

03

 

06 00

E0

D2

06 00

02 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(continued on next page)

20

Page 20
Image 20
Hitachi CP-AW250N user manual Color Temp Offset B, Tint, Sharpness, Active Iris, MY Memory, Aspect, Over Scan, Position