MAINTENANCE (continued)

Replacing the Lamp

1. Switch the projector OFF, remove the power cord from the power outlet, and wait at least 45 minutes for the unit to cool.

2. Prepare a new lamp.

3. Check that the projector has cooled sufficiently, and gently turn it upside down.

4.Remove the two screws as shown in the diagram, and remove the lamp cover.

5. Remove the ond screw, and gently remove the lamp while holding the grips. Touching the inside of the lamp case may result in uneven coloring.

6. Install the new lamp and tighten the one screw firmly.

7. Replace the lamp cover in position and tighten the two screws firmly.

8. Gently turn the projector right-side up.

* Ensure that screws are tightened properly. Screws not tightened fully may result in injury or accidents.

* Do not use the projector with the lamp cover removed.

ENGLISH

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp. When the lamp has been replaced after the LAMP indicator is red, or the CHANGE THE LAMP message is displayed, complete the following operation within ten minutes of switching power ON. The power will be turned off automatically in over 10 minutes.

1.Switch power ON, and press the TIMER button on the remote controller, or the RESET button on the control panel, for approximately three seconds. The ‘LAMP xxxx hr’ message will appear on the lamp timer on the bottom of the screen.

2.Press the MENU button on the remote controller, or the RESET button on the control panel, while the lamp timer is displayed. The ‘LAMP xxxx 0 CANCEL’ message will then appear.

3.Press the and select 0, and wait until the timer display is cleared.

The message functions will not operate properly if the lamp timer is reset without replacing the lamp, or the lamp timer is not reset when the lamp is replaced.