Hitachi CP-X305, CP-X205 $OHUW6HWWLQJV, Lvsod\VDqgFrq¿JxuhvIdloxuh ZduqlqjDohuwVhwwlqjv

Models: CP-X305 CP-X205

1 127
Download 127 pages 51.19 Kb
Page 85
Image 85

&RQÀJXULQJDQG&RQWUROOLQJWKH3URMHFWRUYLDD HE%URZVHU

$OHUW6HWWLQJV

'LVSOD\VDQGFRQ¿JXUHVIDLOXUH ZDUQLQJDOHUWVHWWLQJV

Alert Item

Description

Cover Error

7KHODPSFRYHUKDVQRWEHHQSURSHUO\¿[HG

Fan Error

The cooling fan is not operating.

Lamp Error

The lamp does not light, and there is a possibility that interior

portion has become heated.

 

 

 

Temp Error

There is a possibility that the interior portion has become

heated.

 

 

 

Air Flow Error

The internal temperature is rising.

Lamp Time Error

Lamp time over.

 

Cold Error

There is a possibility that the interior portion has become

overcooled.

 

 

 

Filter Error

Filter time over.

 

Other Error

Other error.

 

If displaying this error, please contact your dealer.

 

Schedule Execution

Schedule Execution error. (

13)

Error

 

 

Lamp Time Alarm

/DPSWLPHRYHU$ODUP7LPHVHWWLQJ

Filter Time Alarm

)LOWHUWLPHRYHU$ODUP7LPHVHWWLQJ

Transition Detector

7UDQVLWLRQ'HWHFWRU$ODUP

"OPTION menu" section of the

Alarm

User's Manual - Operating Guide)

 

“CHANGE THE LAMP” is

³&+$1*(7+(/$03´LVGLVSOD\HG

displayed.

 

 

Cold Start

The power switch is turned on.

2II VWDQGE\PRGH

 

 

 

Authentication Failure

The SNMP access is detected from the invalid SNMP

community.

 

 

 

Refer to "Troubleshooting" section of the User's Manual - Operating Guide for further detailed explanation of Error except Other Error and Schedule Execution Error.