English

3.

Charging

 When the battery is fully charged, the charge status



When the battery is connected to the battery

lamp will bilink in red slowly. (At 1-second

 

charger, charging will commence and the charge

intervals) (See Table 2)

 

status lamp will light in red. (See Table 2)

 

 

NOTE:

 

 

If the charge status lamp flikers in red, pull out the

 

 

plug from the receptacle and check if the battery

 

is properly mounted.

 

 

 

 

 

 

 

 

 

 

 

 

Table 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indications of the lamp

 

 

Charge

Before

Blinks

Lights for 0.5 seconds. Does not light for 0.5

 

 

status

charging

(RED)

seconds. (off for 0.5 seconds)

 

 

lamp (RED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

While

Lights

Lights continuously

 

 

 

 

 

 

charging

(RED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charging

Blinks

Lights for 0.5 seconds. Does not light for 0.5

 

 

 

complete

(RED)

seconds. (off for 0.5 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charging

Flickers

Lights for 0.1 seconds. Does not light for 0.1

Malfunction in the

 

impossible

(RED)

seconds. (off for 0.1 seconds)

battery or the charger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery

overheated.

Overheat

Overheat

Lights

Lights continuously

lamp

standby

(GREEN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unable

to charge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(GREEN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Charging will commence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

when battery cools).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: When standby for cooling battery, UC36YRL cools the overheated battery by cooling fan.

Regarding the temperature of the rechargeable battery.

The temperatures for rechargeable batteries are as shown in the table below, and batteries that have become hot should be cooled for a while before being recharged.

 

Table 3

Rechargeable

Temperatures at which the

batteries

battery can be recharged

 

 

BSL2530

32°F — 122°F (0°C — 50°C)

Regarding recharging time

Table 4 shows the recharging time required according to the type of battery.

Table 4 Recharging time (approx. min.) at 20°C

 

Battery

capacity (Ah)

Battery

Li-ion BATTERY

Voltage

 

 

 

 

3.0 Ah

 

 

 

 

 

 

25.2V

BSL2530

 

60min.

NOTE:The recharging time may vary according to the ambient temperature.

4.Disconnect battery charger from the receptacle.

CAUTION:

Do not pull the plug out of the receptacle by pulling on the cord.

Make sure to grasp the plug when removing from receptacle to avoid damaging cord.

5.Remove the battery from the battery charger. Supporting the battery charger with hand, pull out the battery from the battery charger.

Regarding electric discharge in case of new batteries, etc.

As the internal chemical substance of new batteries and batteries that have not been used for an extended period is not activated, the electric discharge might be low when using them the first and second time. This is a temporary phenomenon, and normal time required for recharging will be restored by recharging the batteries 2 – 3 times.

12