English
SAFETY
IMPORTANT SAFETY INSTRUCTIONS FOR BATTERY CHARGER
WARNING: Death or serious bodily injury could result from improper or unsafe use of battery chargers. To avoid these risks, follow these basic safety instructions:
READ ALL INSTRUCTIONS
1.This manual contains important safety and operating instructions for battery charger Model ET18DM. (Adapter Model
2.Before using battery charger, read all instructions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery.
3.To reduce risk of injury, charge HITACHI rechargeable battery types EB9, EB12, EB14, EB18 series. Other type of batteries may burst causing personal injury and damage.
4.Do not expose battery charger to rain or snow.
5.Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire, electric shock, or injury to persons.
6.To reduce risk of damage to electric plug and cord, pull by plug when disconnecting battery charger.
7.Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress.
If extension cord must be used make sure:
a.That blades of extension cord are the same number, size, and shape as those of plug on battery charger:
b.That extension cord is properly wired and in good electrical condition; and
c.That wire size is large enough for AC ampere rating of battery charger as specified in Table 1.
Table 1
RECOMMENDED MINIMUM AWG SIZE FOR
EXTENSION CORDS FOR BATTERY CHARGERS
AC Input Rating Amperes* |
|
| AWG Size of Cord |
| ||
|
|
|
|
|
|
|
Equal to or | but less |
| Length of Cord, Feet (Meter) | |||
| ||||||
greater than | than | 25 (7.5) | 50 (15) | 100 (30) | 150 (45) | |
0 | 2 | 18 | 18 | 18 | 16 | |
2 | 3 | 18 | 18 | 16 | 14 | |
3 | 4 | 18 | 18 | 16 | 14 |
*If the input rating of a battery charger is given in watts rather than in amperes, the corresponding ampere rating is to be determined by dividing the wattage rating by the voltage