Hitachi FD2 1590 Performance Chart, Fluid Pressure Curves, To find Fluid Outlet Pressure

Models: FD2 1590

1 50
Download 50 pages 32.43 Kb
Page 33
Image 33

Performance Chart - 1040

Test Conditions: Pump tested in water with inlet submerged

 

Fluid Pressure Curves

 

 

A

at 120 psi (0.7 MPa, 7 bar) operating air pressure

 

120

B

at 100 psi (0.7 MPa, 7 bar) operating air pressure

 

(0.84, 8.4)

PressureOutlet bar)(MPa,psi

100

operating air pressure (psi/MPa/bar):

40

C

at 70 psi (0.48 MPa, 4.8 bar) operating air pressure

 

(0.7, 7)

D

at 40 psi (0.28 MPa, 2.8 bar) operating air pressure

 

80

 

 

 

(0.55, 5.5)

To find Fluid Outlet Pressure

 

60

(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and

Fluid

(0.41, 4.1)

1.

Locate fluid flow rate along bottom of chart.

20

 

 

 

(0.28, 2.8)

2.

Follow vertical line up to intersection with selected

 

(0.14, 1.4)

 

operating air pressure curve.

 

0

3.

Follow left to scale to read fluid outlet pressure.

 

 

 

Performance Chart - 1040

5

10

15

20

25

30

35

40

(19)

(38)

(57)

(76)

(95)

(114)

(133)

(152)

Fluid Flow

gpm (lpm)

TI8736A

TI8742A

 

Air Consumption Curves

 

A

at 120 psi (0.7 MPa, 7 bar) operating air pressure

 

B

at 100 psi (0.7 MPa, 7 bar) operating air pressure

 

C

at 70 psi (0.48 MPa, 4.8 bar) operating air pressure

 

D

at 40 psi (0.28 MPa, 2.8 bar) operating air pressure

ConsumptionAir

1.

Locate fluid flow rate along bottom of chart.

To find Pump Air Consumption

 

(scfm or m3/min) at a specific fluid flow (gpm/lpm) and

 

operating air pressure (psi/MPa/bar):

 

2.

Read vertical line up to intersection with selected

 

 

operating air pressure curve.

 

3.

Follow left to scale to read air consumption.

 

60 (0.41, 4.1)

 

40

 

 

 

 

 

 

 

 

/min)

(0.28, 2.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

(m

 

 

 

 

 

 

 

 

 

scfm

20

 

 

 

 

 

 

 

 

(0.14, 1.4)

 

 

 

 

 

 

 

 

 

0

5

10

15

20

25

30

35

40

 

 

(19)

(38)

(57)

(76)

(95)

(114)

(133)

(152)

 

 

 

 

 

Fluid Flow

 

 

 

 

 

 

 

 

gpm (lpm)

 

 

TI8737A

TI8742A

311879F

33

Page 33
Image 33
Hitachi FD2 1590 Performance Chart, Fluid Pressure Curves, To find Fluid Outlet Pressure, Air Consumption Curves