Technical Data - 1590
Technical Data - 1590
Maximum fluid working pressure | 120 psi (0.8 MPa, 8 bar) |
Air pressure operating range | |
Maximum air consumption | 130 scfm |
Air consumption at 70 psi/50 gpm | 42 scfm (see chart) |
Maximum | 100 gpm (379 l/min) |
Maximum pump speed | 200 cpm |
* Gallons (Liters) per cycle | 0.5 (1.9) |
Maximum suction lift | 29 ft (8.83 m) wet, 14 ft (4.26 m) dry |
Maximum size pumpable solids | 3/16 in. (4.8 mm) |
** Maximum Noise Level at 100 psi, full flow | 88 dBa |
** Sound Power Level | 95 dBa |
** Noise Level at 70 psi and 50 cpm | 79 dBa |
| PTFE 220°F (104.4°C) |
Maximum fluid operating temperature is based on the fol- Santoprene® 180°F (82.2°C) | |
lowing maximum diaphragm, ball, and seat temperature | Neoprene 200°F (93°C) |
ratings | EPDM 275°F (135°C) |
| Stainless steel 250°F (121.1°C) |
Air inlet size | 0.5 in. npt(f) |
Fluid inlet size | 2.0 in. Sanitary flange |
Fluid outlet size | 2.0 in. Sanitary flange |
Wetted parts
***All fluid contact materials are
Wetted materials on all models . . . . . . . . . . . . . . . . . . . . 316 SST
Wetted material depending on model. . . . . . . . . . . . . . . . EPDM, Neoprene, PTFE, Santoprene®
*Displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type.
**Noise levels measured with the pump mounted to a solid surface. Sound power measured per ISO Standard
***The pump user must verify that the construction materials meet their specific application requirements.
40 | 311879F |