Hitachi FD2 1590 important safety instructions Maximum fluid working pressure Psi 0.8 MPa, 8 bar

Models: FD2 1590

1 50
Download 50 pages 32.43 Kb
Page 40
Image 40
CAUTION:
Santoprene® may be used only with non-fatty,non-oily foods or alcohols up to 15%.
Non-wetted external parts . . . . . . . . . . . . . . . . . . . . . . . . 300 series stainless steel, polyester (labels), LDPE foam (gasket)
Weight
All models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 lb (40.3 kg) Santoprene® is a registered trademark of the Monsanto Co.
Loctite® is a registered trademark of the Loctite Corporation.

Technical Data - 1590

Technical Data - 1590

Maximum fluid working pressure

120 psi (0.8 MPa, 8 bar)

Air pressure operating range

20-120 psi (0.14-0.8 MPa, 1.4-8 bar)

Maximum air consumption

130 scfm

Air consumption at 70 psi/50 gpm

42 scfm (see chart)

Maximum free-flow delivery

100 gpm (379 l/min)

Maximum pump speed

200 cpm

* Gallons (Liters) per cycle

0.5 (1.9)

Maximum suction lift

29 ft (8.83 m) wet, 14 ft (4.26 m) dry

Maximum size pumpable solids

3/16 in. (4.8 mm)

** Maximum Noise Level at 100 psi, full flow

88 dBa

** Sound Power Level

95 dBa

** Noise Level at 70 psi and 50 cpm

79 dBa

 

PTFE 220°F (104.4°C)

Maximum fluid operating temperature is based on the fol- Santoprene® 180°F (82.2°C)

lowing maximum diaphragm, ball, and seat temperature

Neoprene 200°F (93°C)

ratings

EPDM 275°F (135°C)

 

Stainless steel 250°F (121.1°C)

Air inlet size

0.5 in. npt(f)

Fluid inlet size

2.0 in. Sanitary flange

Fluid outlet size

2.0 in. Sanitary flange

Wetted parts

***All fluid contact materials are FDA-compliant and meet the United States Code of Federal Regulations (CFR) Title 21, Section 177.

Wetted materials on all models . . . . . . . . . . . . . . . . . . . . 316 SST

Wetted material depending on model. . . . . . . . . . . . . . . . EPDM, Neoprene, PTFE, Santoprene®

*Displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type.

**Noise levels measured with the pump mounted to a solid surface. Sound power measured per ISO Standard 9614-1.

***The pump user must verify that the construction materials meet their specific application requirements.

40

311879F

Page 40