Chapter 8 List of Data Settings
8 - 5
Default
Code Function name Monitored data or setting _FF _FEF _FUF
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
A081 AVR function select 00 (always on), 01 (always off), 02 (off during deceleration) 02 00 00 ¯ ¯
AVR
A082 AVR voltage select 200 V class: 200, 215, 220, 230, 240 (V)
400 V class: 380, 400, 415, 440, 460, 480 (V) 200/400230/400 230/460 ¯ ¯ 4-11
A085 Operation mode selection 00 (normal operation), 01 (energy-saving operation), 02 (fuzzy operation) 00
¯ ¯
A086 Energy saving mode tuning 0.1 to 100.0 50.0 { { 4-32
A092 Acceleration (2) time setting 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 15.00 { {
A292 Acceleration (2) time setting,
2nd motor 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 15.00 { {
A392 Acceleration (2) time setting,
3rd motor 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 15.00 { {
A093 Deceleration (2) time setting 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 15.00 { {
A293 Deceleration (2) time setting,
2nd motor 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 15.00 { {
A393 Deceleration (2) time setting,
3rd motor 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 15.00 { {
A094 Select method to switch to
Acc2/Dec2 profile 00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only
when rotation is reversed) 00 ¯ ¯
A294 Select method to switch to
Acc2/Dec2, 2nd motor 00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only
when rotation is reversed) 00 ¯ ¯
A095 Acc1 to Acc2 frequency
transition point 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ ¯
A295 Acc1 to Acc2 frequency
transition point, 2nd motor 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ ¯
A096 Dec1 to Dec2 frequency
transition point 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ ¯
A296 Dec1 to Dec2 frequency
transition point, 2nd motor 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ ¯
4-30
A097 Acceleration curve selection 00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve) 00 ¯ ¯
Operation mode and acceleration/deceleration function
A098 Deceleration curve setting 00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve) 00 ¯ ¯ 4-31
A101 [OI]-[L] input active range start
frequency 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ {
A102 [OI]-[L] input active range end
frequency 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ {
A103 [OI]-[L] input active range start
current 0. to "[OI]-[L] input active range end current" (%) 20. ¯ {
A104 [OI]-[L] input active range end
current "[OI]-[L] input active range start current" to 100. (%) 100. ¯ {
A105 [OI]-[L] input start frequency
enable 00 (external start frequency), 01 (0 Hz) 00 ¯ {
A111 [O2]-[L] input active range start
frequency -400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ {
A112 [O2]-[L] input active range end
frequency -400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ {
A113 [O2]-[L] input active range start
voltage -100. to 02 end-frequency rate (%) -100. ¯ {
External frequency adjustment
A114 [O2]-[L] input active range end
voltage "02 start-frequency rate" to 100. (%) 100. ¯ {
4-14
A131 Acceleration curve constants
setting 01 (smallest swelling) to 10 (largest swelling) 02 ¯ {
Acceleration
and
deceleration
A132 Deceleration curve constants
setting 01 (smallest swelling) to 10 (largest swelling) 02 ¯ {
4-31
A141 Operation-target frequency
selection 1
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via
OI), 04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string
frequency input) 02 ¯ {
A142 Operation-target frequency
selection 2
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via
OI), 04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string
frequency input) 03 ¯ {
A143 Operator selection 00 (addition: A141 + A142), 01 (subtraction: A141 - A142), 02 (multiplication:
A141 x A142) 00 ¯ {
4-13
A145 Frequency to be added 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00 ¯ {
Operation-target frequency
A146 Sign of the frequency to be
added 00 (frequency command + A145), 01 (frequency command - A145) 00 ¯ { 4-14
A150 EL-S-curve acceleration
ratio 1 0. to 50. (%) 25. ¯ ¯
A151 EL-S-curve acceleration
ratio 2 0. to 50. (%) 25. ¯ ¯
A152 EL-S-curve deceleration
ratio 1 0. to 50. (%) 25. ¯ ¯
Acceleration and
deceleration
A153 EL-S-curve deceleration
ratio 2 0. to 50. (%) 25. ¯ ¯
4-31
*1 This setting is valid only when the OPE-SR is connected.