LEGS OR CASTERS

LEGS OR CASTERS

WARNING: THE CABINET MUST BE BLOCKED AND STABLE BEFORE INSTALLING LEGS OR CASTERS.

Legs (Fig. 4)

THREADED HOLE

To install the legs, raise and block the reach-in a minimum of 7" from the floor and thread the legs into the threaded holes on the bottom of the cabinet. The unit must be level in order to operate properly. Turn the adjustable feet in or out as required to level the unit front-to-back and side-to-side.

NOTE: Three-section front opening cabinets come with five legs; the fifth leg should be placed in the front center threaded hole. Failure to install these legs in the proper location may result in damage to the cabinet.

Casters (Fig. 5)

Use casters only on reach-in models that have cord and plug electrical connections.

Raise and block the cabinet a minimum of 7" from the floor. Thread the casters into the holes in the bottom of the cabinet (Fig. 6). Casters with brake should be installed at the front. Securely tighten the caster with the octagon shaped bolt head underneath — not the round flange on top.

Shelves (Fig. 6)

If purchased, the shelves and shelf clips are shipped with the cabinet. Insert the shelf clips into the pilaster and install the shelves. Index holes are provided in the pilaster to help in leveling the shelves.

RAISE Casters (Fig. 5)LOWER

PL-56125 Shelves (Fig. 6)Compressor Mounts

Fig. 4

Manual background BOLT

PL-53353

Fig. 5

Bonus shelves are provided to fill the space between the shelves. These are positioned and supported by the shelves.

NOTE: Loosen all thumbscrews which secure shelf pilasters and light cover(s) prior to placing product in the cabinet. Thumbscrews should be loose enough to remove with your fingers so parts can be readily removed for cleaning without the use of tools. Failure to comply with this request will invalidate the NSF listing.

Compressor Mounts

Some reach-in refrigeration models have the compressor specially mounted to help prevent damage during shipment. If the compressor is mounted on shipping blocks, remove the shipping blocks before operating the compressor. If the compressor is mounted on springs, refer to the tag attached to the compressor.

 

PILASTER

COLD AIR

 

DUCT

 

 

INDEX

BONUS

HOLE

 

SHELF

SHELF

 

CLIP

 

SHELF

PL-50910

 

Fig. 6

– 4 –