Program Review

Program Review

During normal Operation Mode, with the SET CLOCK light blinking rapidly . . .

Current Clock Time = HH:MM

# Blinks = HH

# Blinks (times 5) = MM

#Blinks (times 5) =

DEFROST DURATION

Fig. 15

Initiating a Manual Defrost

Press the SET button until the SET CLOCK, PROGRAM and DEFROST ON lights are lit; then release the SET button and all three lights go off for two seconds. After that, all three lights begin to blink. The number of blinks of a light corresponds to the programmed value for that light (Fig. 15). A three second pause follows the last blink before the cycle repeats. The Review Mode's sequence of blinking lights repeats ten times to give you plenty of chances to count the number of blinks for each light. Review Mode can be stopped at any time by pressing the SET button for 3 seconds; when the SET button is released, normal Operation Mode returns with the SET CLOCK light blinking rapidly.

The SET CLOCK light blinks from 1 to 12 times to indicate the TIME CLOCK HOUR. If the final blink for the hour count remains on for two seconds, it indicates PM; if the final blink for the hour count is a normal blink, it indicates AM.

While the SET CLOCK light is blinking the HOUR, the PROGRAM light blinks from 0 to 11 times to indicate the TIME CLOCK MINUTES to the nearest 5 minutes after the hour: 0 blinks = 0 minutes, 1 blink = 5 minutes, 2 blinks = 10 minutes, . . .

11 blinks = 55 minutes.

While the SET CLOCK light is blinking the HOUR and the PROGRAM light is blinking the MINUTES, the DEFROST ON light blinks from 0 to 11 times to indicate the DEFROST DURATION setting to the nearest 5 minutes: 0 blinks = 0 minutes, 1 blink = 5 minutes, 2 blinks = 10 minutes, . . .

11 blinks = 55 minutes.

After the ten blinking sequences are done or after Review Mode has been stopped, normal Operation Mode returns with the SET CLOCK light blinking rapidly.

During normal Operation Mode, with the SET CLOCK light blinking rapidly . . .

Press the MANUAL DEFROST button for about 3 seconds until the DEFROST ON light comes on. The Defrost Cycle is started and continues for the amount of time programmed for DEFROST DURATION (page 7).

Cancelling a Defrost Cycle

While a Defrost Cycle is in progress, the DEFROST ON light is lit. A Defrost Cycle that is in progress can be terminated by pressing the MANUAL DEFROST button for 3 seconds. The DEFROST ON light goes off.

The normal DEFROST SCHEDULE continues to operate as programmed.