TROUBLESHOOTING | |
|
|
Symptoms | Possible Causes |
|
|
Mixer will not start. | Circuit protector is in open position - check fuse or disconnect switch. |
| Mixer is overloaded. |
| Wire cage is not in the closed position. |
| Bowl is not in closed (locked) position. |
|
|
Agitator touches bowl. | Bowl is not in closed (locked) position. |
| Improper agitator clearance - see Maintenance for adjustment |
| procedure. |
| Agitator is not installed properly. |
|
|
Planetary seal squeaks. | Seal requires occasional lubrication - see Maintenance. |
|
|
Timer displays error code (ErXX). | If the error code is flashing - wait for mixer to clear error condition. |
| If mixer continues to stop and timer displays flashing error code, |
| disconnect electrical power from mixer for 1 minute, then reconnect. |
| If symptoms still exist, contact your local Hobart Service office. |
|
|
Alternated message of "b_in" on | Bowl is not in all the way. |
SPEED display. | If message of "b_in" appears again after a corrective action, |
| disconnect electrical power from mixer for 1 minute, then reconnect. |
| If symptoms still exist, contact your local Hobart Service office. |
|
|
Alternated message of "b_up" on | Bowl is not up all the way. |
SPEED display. | If message of "b_up" appears again after a corrective action, |
| disconnect electrical power from mixer for 1 minute, then reconnect. |
| If symptoms still exist, contact your local Hobart Service office. |
|
|
Alternated message of "b_gd" on | Wire cage is not closed completely. |
SPEED display. | If message of "b_gd" appears again after a corrective action, |
| disconnect electrical power from mixer for 1 minute, then reconnect. |
| If symptoms still exist, contact your local Hobart Service office. |
|
|
Message of "HI" and "LOAd" on | Make sure you are not using STIR to develop dough product. |
displays. |
|
|
|
SERVICE
If service is needed on this equipment, contact your local Hobart Service office.