12.Slide strain relief bracket into the panel per Fig. 11.
13.Attach the strain relief bracket to dishwasher with a #10 screw per Fig. 12.
14.Make DWT2 cold water valve harness (919862) connections with wiring harness (814267) per Fig. 13.
15.Connect harness ground wire to grounding point on base of dishwasher per Fig. 14.
NOTE: Dress valve electrical conduit so it will not sustain damage when the machine is moved for service or cleaning.
16.Locate existing wiring diagram on dishwasher unit. Locate
Operation
1.Make sure cold water supply line valve is open and pressure gage is set to 20 psi flowing for this drain water tempering kit.
2.Check for and correct any plumbing leaks.
3.Check water and drain hoses for kinks which could hinder operation of the Drain Water Tempering Kit or dishwasher.
4.Check unit for proper operation of Drain Water Tempering Kit.
5.Adjust regulator on cold water line for acceptable temperatures per local code.
F25230 (Rev. A, May 2008) | Page 8 of 8 | © HOBART 2008 |