19
FAULT FINDING.
Fault Possible Cause Remedy
Machine fails to start. Blown fuse or circuit breaker Check and replace faulty fuse.
open.
Bowl support is not in the Place bowl in up position.
correct operating position.
Bowl guard is not in the correct Place guard in front and
operating position. center position.
Speed selection lever is not in Set to required speed
correct operating position. position.
Check gear lever position. If Move gear lever to desired
not correctly engaged, mixer speed.
will not start.
Check that electrical supply is Plug in and switch on.
switched on.
Mixer is overloaded. Decrease amount of load.
Machine still fails to operate. Call local service centre.
Motor starts but shaft Gear selection lever is Move to the correct speed.
fails to turn. incorrectly positioned.
Planetary shaft still fails to turn. Call local service centre.
Agitator touches bowl. Bowl clamp(s) are not closed. Close bowl clamp(s).
Improper agitator clearance. See MAINTENANCE for
adjustment procedure.
Bowl clamp(s) are improperly See MAINTENANCE for
adjusted. adjustment procedure.
Planetary seal squeaks. Seal requires occasional See MAINTENANCE.
lubrication.