ELECTRICAL CONNECTION

ELECTRICAL CONNECTION

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.

The mixer grinder is provided with a cord and plug and only requires that it be connected to an appropriately sized, grounding-type receptacle. Refer to the machine data plate (Fig. 5) and Electrical Data, below.

ELECTRICAL DATA

 

 

 

Minimum Circuit Ampacity

 

 

 

 

 

Model

Horsepower

Volts / Hertz / Phase

Maximum Protective Device

Receptacle

Plug

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

208 / 60 / 3

30

W

G

Y

 

 

 

 

 

 

 

 

 

built before October, 2000

 

 

Plug:

 

L21-30P

 

 

 

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L21-30R

 

 

 

 

208 / 60 / 3

 

 

X

 

 

 

 

 

 

 

 

 

 

 

MG1532 7.5 HP Grind built after October, 2000

30

G

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug:

 

L15-30P

MG2032 & 1 HP Mix

240 / 60 / 3

 

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L15-30R

 

 

 

 

 

 

 

X

 

 

 

 

 

 

 

G

Y

 

 

 

 

480 / 60 / 3

20

Plug:

 

L16-20P

 

 

 

 

 

 

 

 

 

 

Z

 

 

 

 

 

 

 

 

L16-20R

 

 

 

5 HP Grind

 

 

 

 

 

 

 

MG1532

 

208 - 240 / 60 / 1

30

 

 

Plug:

L6-30P

 

& 1 HP Mix

 

 

 

 

 

 

 

 

 

 

 

 

L6-30R

 

 

Compiled in accordance with the National Electrical Code, NFPA-70, latest edition.

CHECK MOTOR ROTATION (Three-Phase Machines Only)

With the grinder cylinder in place and the hopper lid closed, check the rotation before making a permanent electrical connection by first pushing the MIX-GRIND START switch and then pushing the STOP switch (Fig. 4). The mixing arm and worm should both rotate counterclockwise, when viewed from the machine's front.

If the mixing arm and worm rotate clockwise, correct the rotation using the following procedure:

DISCONNECT THE ELECTRICAL POWER SUPPLY and interchange any two of the incoming power supply leads. Reconnect the power supply and push the MIX-GRIND START switch to verify that both the worm and the mixer arm rotate counterclockwise as viewed from the front of the machine.