Hobart ML-104655, ML-104651, ML-104654, ML-104650 manual Operation, CONTROLS Fig

Models: ML-104650 ML-104655 ML-104654 ML-104651

1 8
Download 8 pages 35.13 Kb
Page 6
Image 6
CONTROLS (Fig. 2)

CONTROLS (Fig. 2)

START

MIX MIX-GRIND

STOP

STOP

FOOT SWITCH ACTIVATOR

ON

OFF

Fig. 2

SPANNER WRENCH

THUMB SCREW

BUSHING RETAINER

GRINDER ATTACHMENT

ADJUSTING RING

OPERATION

START BUTTONS

MIX — Starts rotating the mix arm. Use the Stop Button to stop mixing.

MIX-GRIND — Starts rotating both mix arm and worm. Use the Stop Button to stop mixing and grinding.

STOP BUTTON — Turns the mixer-grinder off.

FOOT SWITCH ACTIVATOR ON-OFF — When in the On position, the Mix and Mix-Grind Start Buttons are inoperable and the accessory Foot Switch can be used to Mix-Grind ONLY. The indicator light shows when the Foot Switch is On.

HOPPER GUARD INTERLOCK — The mixer-grinder has a magnetic actuated interlock in the hopper. The hopper guard (lid) must be closed before the machine can operate. Raising the hopper guard opens the electrical circuit and makes the machine inoperative.

MIXING ARM

SEAL

MACHINE DATA

PLATE

WORM

PL-52466

Fig. 3

– 6 –