– 9 –
Clean completely around the RING GUARD by working a
moistened, folded paper towel between the RING GUARD and the
KNIFE (Fig. 15).
Wash, rinse and sanitize both sides of the KNIFE by wiping
outward from the center. Never clean any part of the slicer
with steel pads.
Carefully reassemble the plastic RING GUARD COVER by putting
it in position using the three guide PINS (Fig. 14). Carefully
reassemble the TOP KNIFE COVER (Fig. 13) by putting it in
position over the plastic RING GUARD COVER using the three
guide PINS. Secure both RING GUARD COVER and TOP KNIFE
COVER by turning the LATCH KNOB (Fig. 7) counterclockwise
while lowering the TOP KNIFE COVER; then release the LATCH
KNOB and turn it clockwise until snug.
Reassemble the SHARPENER by lowering it straight down so the
ROD AND PIN fit the SLOT on the SHARPENER MOUNT (Fig. 12).
Replace the DEFLECTOR, if present, below the KNIFE (Fig. 16);
also, refer to page 3.
To reinstall the PRODUCT TRAY, hold it with both hands and lower
it so the bottom of the SUPPORT ARM fits on the CARRIAGE HINGE
PINS (Fig. 17). Return the PRODUCT TRAY to the GAUGE PLATE by
tilting the PRODUCT TRAY to the left. Turn the KNOB on the
SUPPORT ARM in either direction until it moves inward, then turn
the KNOB clockwise until snug.
The LIFT ASSIST (Fig. 18) underneath the machine, allows you to
lift the right side of the slicer base with little effort — the slicer
is completely supported so you can clean underneath. Press
down on the right side of the slicer to lower it back to the table.
NOTE: Failure to follow use, care, and maintenance instructions may void your Hobart warranty.