WS-C206/WS-C208 Hobart Compact Water Softener Installation Instructions - DISC SELECTION

DISC SELECTION

DISC SELECTION WS-C206/WS-C208

The amount of hardness removed (in compensated gpg) will be based on the amount of brine and the meter disc selected.

1.Test water supply for hardness and iron content. Use water analysis test kit available through Pro Products Inc. The recommended kit is #2401 Field Analysis Kit. To order test kit contact Pro Products at 800-285-9176 or visit www.ProProducts.com.

2.Determine the compensated hardness for raw water.

A.Hardness value in gpg.

B.Ferrous iron value in ppm multiplied by 3.

C.Add values together.

3.Salt setting is predetermined by height of float cup. Float cup setting is listed in Specification Table.

Specifications

WS-C206

WS-C206

Salt usage / generation

0.5 lbs.

1.0 lbs.

Capacity

1,746 grains

2,527 grains

Efficiency

3,492 gr./lb.

2,527 gr./lb.

Dosing

2.7 lbs./cu. ft.

5.5 lbs./cu. ft.

Float cup setting

5.25"

6.25"

Specifications

WS-C208

WS-C208

Salt usage / generation

1.0 lbs.

1.4 lbs.

Capacity

4,094 grains

4,818 grains

Efficiency

4,094 gr./lb.

3,442 gr./lb.

Dosing

2.5 lbs./cu. ft.

3.5 lbs./cu. ft.

Float cup setting

5.25"

5.75"

WS-C206 Disc Selection

Disc Number

1

2

3

4

5

6

7

8

Compensated Hardness

2

5

8

10

13

15

18

20

at .5 lb. setting *

 

 

 

 

 

 

 

 

Compensated Hardness

4

8

11

15

19

23

27

30

at 1.0 lb. setting *

 

 

 

 

 

 

 

 

Gallons Between

583

282

194

146

117

97

83

73

Regeneration

 

 

 

 

 

 

 

 

Regeneration Gallons

9.1

9.1

9.1

9.1

8.4

6.6

5.4

4.4

Per Minute @ 15 psig.

 

 

 

 

 

 

 

 

* Compensated hardness in gpg = Hardness + (3 x Fe in ppm)

 

 

 

 

Page 9 of 10

 

F25311 Rev. A (0913)