2-5. Setting Gun Polarity For Wire Type
Shown As Shipped – Set For Electrode Positive
(DCEP) For Solid Steel Or Aluminum Wires
(GMAW Process).
Wire Drive Assembly | Work Clamp Lead To |
Lead To Positive (+) | Negative |
Output Terminal | Terminal |
GUN POLARITY
CHANGEOVER CONNECTIONS
Reverse Lead Connections – For Electrode Negative (DCEN) For Flux Cored Wires (FCAW Process). Drive Assembly Becomes Negative
1
3 4
1Polarity Changeover Label
2Wire Drive Assembly
3Positive (+) Output Terminal
4Negative
Always read and follow wire manufacturer’s recommended polarity.
Close door.
Tools Needed:
3/4 in
2
Ref. 802 472