2-8. Changing Input Voltage From 230 Volts To 200 Volts

2

3

1

Tools Needed:

5/16, 3/8 in

Cut cable ties as necessary.

1230 Volt Lead

2Tubing

Locate lead marked 230 VAC. Slide tubing down and disconnect lead splice.

Fold tubing over 230 volt lead stub and secure.

3 200 Volt Lead

Locate lead marked 200 VAC. Slide tubing down, and connect 200 volt lead stub to top half of the for- mer 230 volt lead, and secure with existing hardware.

Slide tubing over connection and secure.

Ref. 801 878-B

2-9. Electrical Service Guide

Input Voltage

200

230

 

 

 

Input Amperes At Rated Output

30

26

 

 

 

Max Recommended Standard Fuse Rating In Amperes 1

 

 

Time-Delay 2

35

30

Normal Operating 3

45

40

 

 

 

Min Input Conductor Size In AWG/Kcmil

10

10

 

 

 

Max Recommended Input Conductor Length In Feet (Meters)

97

128

(29)

(39)

 

 

 

 

Min Grounding Conductor Size In AWG/Kcmil

10

10

 

 

 

Reference: 1999 National Electrical Code (NEC)

1Consult factory for circuit breaker applications.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).