Hobart Welding Products 2250 Installing Work Clamp, Setting Gun Polarity For Wire Type

Models: 2250

1 40
Download 40 pages 9.77 Kb
Page 15
Image 15

2-5. Installing Work Clamp

2

3

4

1 Work Cable

Route cable out front panel opening from inside.

2Negative (–/Black) Output Terminal

Connect cable to terminal.

3Hardware

4Work Clamp

Route cable through clamp handle and secure as shown.

Close door.

1

Tools Needed:

 

 

1/2, 3/4 in

 

Ref. ST-802 285 / Ref. ST-801 566

2-6. Setting Gun Polarity For Wire Type

 

1

 

Ref. ST-192 432

2

3

1Polarity Changeover Label

2Positive (+/Red) Output Terminal

3Negative (–/Black) Output Terminal

Always read and follow wire manufacturer’s recommended polarity.

Close door.

Tools Needed:

3/4 in

Ref. ST-801 875

OM-192 440 Page 11