Hobart Welding Products 500 manual Remote Amperage Control Receptacle, Electrical Service Guide

Models: 500

1 36
Download 36 pages 34.26 Kb
Page 21
Image 21

3-10. Remote Amperage Control Receptacle

1 Remote Amperage Control

Receptacle RC1

2 Keyway

2

To connect remote amperage con- trol to receptacle, insert plug and turn clockwise until tight.

1

 

 

 

Ref. ST-800 040

3-11. Electrical Service Guide

 

 

 

 

 

 

 

 

 

 

 

50 Hertz Models

 

500 Amp Model

 

 

 

 

 

 

Input Voltage

220

 

380

 

440

 

 

 

 

 

 

Input Amperes At Rated Output

103

 

60

 

51

 

 

 

 

 

 

Max Recommended Standard Fuse Rating In Amperes 1

 

 

 

 

 

Time-Delay 2

100

 

60

 

50

Normal Operating 3

125

 

70

 

60

 

 

 

 

 

 

Min Input Conductor Size In AWG/Kcmil

4

 

8

 

8

 

 

 

 

 

 

Max Recommended Input Conductor Length In Feet (Meters)

193

 

258

 

346

(59)

 

(79)

 

(105)

 

 

 

 

 

 

 

 

 

Min Grounding Conductor Size In AWG/Kcmil

6

 

8

 

10

 

 

 

 

 

 

Reference: 1999 National Electrical Code (NEC)

1Consult factory for circuit breaker applications.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

OM-201 444 Page 17