3-12. Connecting Input Power

A. Placing Jumper Links

Tools Needed:

3/8 in

2 1

Jumper links allow operation on dif- ferent input voltages and are facto- ry set for the highest input voltage.

Check input voltage available at site.

Open rear panel access door to check jumper links.

1 Input Voltage Label – Only One Is On Unit

Look at jumper links and compare link position with unit label.

2 Input Voltage Jumper Links

Move links to match input voltage. For example, use 230 volts position when 230 volts input power is avail- able.

Close door or go on to 3-12B.

220 VOLTS

L1 L2 L3

380 VOLTS

440 VOLTS

L1

L2

L3

L1

L2

L3

S-021 148-A

ssb5.1 2/92 – Ref. ST-800 042

OM-201 444 Page 18