TROUBLESHOOTING

If any abnormality arises during use, please check the following points

SYMPTOMS

POSSIBLE

CORRECTION

CAUSES

 

 

 

 

 

Unit does not turn on

Batteries have

Replace them with

when the

run down.

two new AA alkaline

START/STOP

 

batteries.

button is pushed.

 

 

Battery polarities

Re-insert the batteries

 

have been positioned

in the correct

 

incorrectly.

positions.

 

 

 

EE measurement

Cuff has been placed

Wrap the cuff

error symbol shown

incorrectly.

properly so that it is

on display or the

 

positioned correctly.

blood pressure value

 

 

Did you talk or move

Measure again.

is displayed

during measurement?

Keep arm steady

excessively low

 

during measurement.

Shaking of the arm

(or high).

with the cuff on.

 

 

 

 

 

 

E1 error symbol

Air circuit abnormality.

Check cuff connection.

shown on display

Cuff tube may not be

Measure again.

 

plugged into monitor

 

 

correctly.

 

 

 

 

E2 error symbol

Inflation pressure

Turn the unit off, then

shown on display

exceeding 300 mmHg.

measure again.

 

 

 

E3 error symbol

Error determining

Measure again.

shown on display

measurement data.

 

 

 

 

CA appears on

Recalibration alert.

Refer to page 25 for

display

more information.

 

 

 

 

Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page.

SPECIFICATIONS

Power Source:

Four 1.5V DC (AA) batteries

 

 

Measurement

Oscillometric

Method:

 

 

 

Measurement

Pressure: 40~280 millimeters mercury (mmHg)

Range:

Pulse: 40~199 beats/minute

 

 

Accuracy:

Pressure: ±3 mmHg

Pulse: ±5% of reading

 

 

 

Pressure Sensor:

Semi-conductor

 

 

Inflation:

Manual Inflation

 

 

Deflation:

Automatic Pressure release valve

Memory Capacity:

60 memories

Auto-shut-off:

1 minute after last button operation

 

 

Operation

Temperature: 50°F~104°F (10°C ~40°C)

Environment:

Humidity: Less than 85% R.H.

 

 

Storage

Temperature: -4°F~140°F (-20°C~60°C)

Environment:

Humidity: Less than 85% R.H.

Weight:

.40 lbs/181 grams (without batteries)

 

 

Arm

Standard size adult arm cuff:

Circumference:

9"–13" (23 – 33 cm)

 

 

Dimensions:

4.9"(L) x 4"(W) x 2.5"(H)

125mm(L) x 102mm(W) x 63mm(H)

 

 

 

 

Type BF

 

Device and cuff are designed to provide

 

special protection against electrical shocks.

 

 

Note: These specifications are subject to change without notice.