BAR AND CHAIN COMBINATIONS

BAR AND CHAIN COMBINATIONS

Length of Bar

Guide Bar Part Number

Chain Part Number

14 in.

PS06331

984296005

16 in.

PS06338

PS06285

TROUBLESHOOTING

Problem

Possible Cause

Solution

 

 

 

 

Engine will not start.

No spark.

 

Check spark. Remove air filter cover. Remove spark plug from

[Make sure ignition

 

 

cylinder. Reattach the spark plug wire and lay spark plug on top

switch is in the RUN

 

 

of cylinder with the metal part of plug touching the cylinder. Pull

( l ) position.]

 

 

the starter rope and watch for spark at spark plug tip. If there is no

 

 

 

spark, repeat test with a new spark plug.

 

Engine is flooded.

With the ignition switch OFF, remove spark plug. Move choke

 

 

 

lever to RUN position (pushed in completely) and pull starter cord

 

 

 

15 to 20 times. This will clear excess fuel from engine. Clean and

 

 

 

reinstall spark plug. Set ignition switch to RUN ( l ) position. Push

 

 

 

and fully release primer bulb 7 times. Pull starter three times with

 

 

 

choke lever at RUN. If engine does not start, move choke lever to

 

 

 

HALF CHOKE and repeat normal starting procedure. If engine still

 

 

 

fails to start, repeat procedure with a new spark plug.

 

 

 

Engine starts but will

Carburetor requires “L”

Contact an authorized service center for carburetor adjustment.

not accelerate prop-

(Low Jet) adjustment.

 

erly.

 

 

 

 

 

 

Engine starts, then

Carburetor requires “L”

Contact an authorized service center for carburetor adjustment.

dies.

(Low Jet) adjustment.

 

 

 

 

Engine starts but will

Carburetor requires “H”

Contact an authorized service center for carburetor adjustment.

not run properly at

(High Jet) adjustment.

 

high speed.

 

 

 

 

 

 

Engine does not reach

Oil/fuel mixture incorrect.

Use fresh fuel and the correct 2-cycle oil mix ratio.

full speed and/or emits

Air filter is dirty.

 

Clean air filter. Refer to Cleaning the Air Filter in the Maintenance

excessive smoke.

 

 

 

section of this manual.

 

 

 

 

Spark arrestor screen is

Clean spark arrestor screen. Refer to Cleaning the Spark Arresting

 

dirty.

 

Muffler in the Maintenance section of this manual.

 

Carburetor requires “H”

Contact an authorized service center for carburetor adjustment.

 

(High Jet) adjustment.

 

 

 

 

 

Engine starts, runs,

Carburetor

requires

Turn idle speed screw “T” clockwise to increase idle speed.

and accelerates but

adjustment to idle speed.

Refer to Adjusting the Carburetor in the Maintenance section of

will not idle.

 

 

this manual.

Chain turns at idle.

Carburetor

requires

Turn idle speed screw “T” counterclockwise to decrease speed.

 

adjustment to idle speed.

Refer to Adjusting the Carburetor in the Maintenance section of

 

 

 

this manual.

 

Air leak in the intake

Contact an authorized service center for a rebuild kit.

 

system.

 

 

 

 

 

 

 

 

 

32