Homelite UT15522F manual General Maintenance, See Figures, Spool Retainer

Models: UT15522F

1 14
Download 14 pages 51.86 Kb
Page 10
Image 10
MAINTENANCE

MAINTENANCE

WARNING:

When servicing, use only identical replacement parts. Use of any other parts may create a hazard or cause product damage.

GENERAL MAINTENANCE WARNING:

Always wear safety goggles or safety glasses with side shields during tool operation. If operation is dusty, also wear a dust mask.

WARNING:

Before inspecting, cleaning, or servicing the machine, shut off engine, wait for all moving parts to stop, and disconnect spark plug wire and move it away from spark plug. Failure to follow these instructions can result in serious personal injury or property damage.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use. Use clean cloths to remove dirt, dust, oil, grease, etc.

EZ LINE™ TAP ADVANCE SYSTEM WARNING:

Do not at any time let brake fluids, gasoline, petroleum- based products, penetrating oils, etc., come in contact with plastic parts. Chemicals can damage, weaken or de- stroy plastic which may result in serious personal injury.

You can often make adjustments and repairs described here. For other repairs, have the trimmer serviced by an authorized service dealer.

EZ LINETAP ADVANCE SYSTEM

SPOOL REPLACEMENT

NEW PREWOUND SPOOL

See Figures 7 - 8.

If replacing string only, refer to String Replacement later in this manual.

Use only .080 in. (2.0 mm) diameter monofilament string. Use the manufacturer’s replacement parts for best perfor- mance.

Stop the engine, disconnect the spark plug wire or dis- connect from the power supply. Hold the string head and unscrew the spool retainer. Turn clockwise.

Remove the empty spool from the string head. Use the spring from the empty spool if one is not provided with the new spool and string.

To install the new spool, make sure the two strings are captured in the slots opposite each other on the new

SPOOL

RETAINER

Fig. 7

SPRING

SLOTS

EYELETS

STRING HEAD

SHAFT

Fig. 8

spool. Make sure the ends of each string is extended approximately 6 in. beyond each slot.

Thread the strings into the eyelets in the string head. Carefully push the spool into the string head (gently pull the strings to the outside if necessary). When the spool is positioned in the string head, grasp the strings and pull sharply to release them from the slots in the spool.

Push down and turn the spool counterclockwise until it no longer turns. Hold the spool down and rotate clockwise a small amount. Release the spool. The spool should be locked down in the string head. If not, hold down and rotate until locked.

Make sure the string head and the spool retainer are installed on the shaft by turning the retainer counterclock- wise to tighten.

Pull the strings again to rotate the spool into cutting position. Push the spool retainer down while pulling on string(s) to manually advance the string and to check for proper assembly of the string head.

10

Page 10
Image 10
Homelite UT15522F General Maintenance, Ez Line Tap Advance System Spool Replacement New Prewound Spool, See Figures