22
AC APPLICATIONS
Make sure that the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than 30 minutes.
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance,
and determine whether the problem is the appliance or the rated
load capacity of the generator has been exceeded.
Make sure that it is in good working order. Faulty appliances or
power cords can create a potential for electrical shock.
Before connecting an appliance or power cord to the generator:
Limit operation requiring maximum power to 30 minutes.
Maximum power is:
Substantial overloading will switch off the AC circuit breaker.Exceeding the time limit for maximum power operation or slightlyoverloading the generator may not switch the AC circuit breaker OFF,but will shorten the service life of the generator.For continuous operation, do not exceed the rated power.
Rated power is:
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
3.0 kVA
2.6 kVA