25
Disconnecting the battery charging cable:
BLACK LEAD
REDLEAD
BATTERY CHARGING CABLE
Stop the engine.
Disconnect the black lead of the battery charging cable from the
negative ( ) battery terminal.
Disconnect the red lead of the battery charging cable from the
positive ( ) battery terminal.
Disconnect the battery charging cable from the DC receptacle of the
generator.
Do not start the vehicle while the battery charging cable is connectedand the generator is running. The vehicle or the generator may bedamaged.An overloaded DC circuit, excessive current drawn by the battery, or a
wiring problem will trip the DC circuit protector (the yellow indicator
inside the clear circuit protector button will pop out). If this happens,
wait a few minutes before pushing in the circuit protector button to
resume operation. If the circuit protector continues to go OFF,
discontinue charging and see your authorized Honda generator dealer.
Connect the vehicle battery ground cable to the negative ( ) battery
terminal.
1.
2.
3.
4.
5.
09/02/10 18:44:38 31Z03701_026