Voltage Selector Switch (Dual Voltage System)
The voltage selector switches the main power carrying windings of the
generator to produce “120V ONLY” or “120/24OV”. If a 240V appliance
is connected to the 4-prong receptacle, the switch must be in the “120/
24OV” position. If a 120V appliance ONLY is being connected to any of
the 120V 3-prong receptacles, select the “120V ONLY” position.
120/24OV: The 120V and 120/24OV receptacles can be used
simultaneously.
120V ONLY: ONLY the 120V receptacles can be used. Do not use the
120/24OV receptacle in this position. Rated power will
be available at the 30A 120V locking plug receptacle.
VOLTAGE SELECTOR SWITCH
I
17