Periodic maintenance and adjustment is necessary to keep the
generator in good operating condition. Perform the service and
inspection at the intervals shown in the maintenance schedule below.
m
Exhaust as contains poisonous carbon monoxide. Shut off the
engine be
3 ore performing any maintenance. If the engine must be run,
make sure the area is well-ventilated.
Use only genuine HONDA parts or their equivalent for maintenance
or repair. Replacement parts which are not of equivalent quality may
damage the generator.
Maintenance Schedule
\ REGULAR SERVICE PERIOD (3)
ITEM Each First Every Every Every
month 3 months 6 months year
.
Valve clearance Check-Readjust I
O(2)
.
Fuel tank and filter Ciean I
O(2)
*
Fuel line Check Every 2 years (Replace if necessary) (2)
NOTE:
l
Emission related items.
(I Kervice more frequently when used in dusty areas.
(2)These items should be serviced by an authorized Honda generator dealer, unless the owner
has the proper tools and is mechanically proficient. See the Honda Shop Manual.
(3)For commercial use, log hours of operation to determine proper maintenance intervals.
(4)Check the GFCI before each use if the generator is stored outside unprotected; otherwise,
test the GFCI monthly and record the test results on the fuel tank.
(5)Once each month.