20
AC Receptacle Selection
Power Producing Circuits
EM3800SX:
POWER
CIRCUIT1
POWER
CIRCUIT2
POWERCIRCUIT 1
POWERCIRCUIT 2
120V30A
120V20A (in total)
120V20A (in total)
120V/240V 120VONLY
& 120/240V20A
4A 4B
4A
4B
The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals,4A and 4B.
This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles1, 2, and 3.