37
OPERATION
ReceptacleSwitch Position Available Power
120V ONLY Position120V/240V Position
Power Producing
Circuit
Voltage Selector Switch
Set of
Receptacles
Total Current
Available
The power available to each receptacle depends on the position of the
voltage selector switch.
1
2
3
4A
4B
1
2
3
4A-4B
120 V ONLY
120 V/240 V
30 A at 120 V
20 A at 120 V
20 A at 120 V
30 A at 120 V
None
18.8 A at 120 V
18.8 A at 120 V
18.8 A at 120 V
18.8 A at 240 V
1
2
134B
24A 18.8 A
18.8 A
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles.You must, however,
make sure the load on any receptacle does notexceed its available
power shown in the preceding tableand the total load does not
exceed 37.5 amps.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide theload between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producingc ircuitthat can
produce a maximumof 18.8 a mps.
07/12/21 14:03:28 31Z11710_038