SERVICING YOUR GENERATOR
Battery Charging
Battery Installation
The battery gives off explosive
hydrogen gas during normal
operation.
A spark or flame can cause the
battery to explode with enough
force to kill or seriously hurtyou.
Wear protective clothing and a face
shield, or have a skilled mechanic
do the battery maintenance.
Connect the battery negative ( ) cable to the battery negative ( )
terminal and tighten the bolts ecurely.
Slide the battery boot over the positive ( ) cable and terminal.
Connect the battery positive ( ) cable to the battery positive ( )
terminal first and tighten the bolt securely.
Install the battery into the generator.
Clean the outside of the battery and the battery compartment with a
solution of baking soda and water.
Connect the battery chargerf ollowing the manufacturer’s
instructions.
The battery is rated at 11.2 Ah (ampere-hours).Charging current
should equal 10% of the battery’s ampere-hour rating. A battery
charger should be used that can be adjusted to deliver1.1 amps.
Charge the battery 5 10 hours.
Install the battery strap.
Install the maintenance cover in the reverseorder of removal (see
page ).
Never operate the generatorwithout the maintenance cover in place,
as poor engine and generator performancewill result.