19
CONTROL & FEATURES
i-Monitor
i-Monitor Display Mode1 Total OperatingHours
i-Monitor Display
Display Backlight Flashes
i-Monitor at Startup
SINGLE-DIGIT
SCREENDISPLAY
FOUR-DIGIT
SCREENDISPLAY
i-MONITORBUTTON
TM
TM
The i-Monitor is a user interface that allows the operator toview
(when the generator is running) total operatingtime in hours,
generator output, engine RPM,battery voltage and error messages.
The different display modes are selected by pressing the i-Monitor
button.
This mode displays the total operating hours of the generator.When
the generator is running, the total operating time accumulates. If the
total operating time is less than one hour,the numeric display will be
‘‘0.’’ When the operating time is one houror greater, the display will
be ‘‘1’’ or ‘‘2’’ and so on. Base the generator’smaintenance schedule
on the accumulated time displayed.
The i-Monitor display is divided into two screens. The single-digit
screen displays the i-Monitor modewhich is represented by a number
1 through 4. The four-digit screendisplays the f ourmode values or
any activated error messages.
If the key is left in the ON position for over 30 seconds without starting
the engine, the display will startto flash.
During start up, the i-Monitordisplay and all three indicators will
simultaneously blink once. The condition of the i-Monitor display
andallthreeindicatorscanbecheckedwiththeaidofanobserver.
Once the generator is running, the Outputindicator (green) and the
i-Monitor display will remain lit.
07/03/13 16:23:06 31Z11600_020