A-1 Specifications

7300A Digital Control Portion:

Ranges:

Three Programmable Ranges, field selectable

 

 

within limits (application dependent) and Auto

 

 

Ranging

 

Display:

2 line by 20 alphanumeric VFD accompanied

 

 

by 5 digit LED display

 

Signal Output:

4-20mADC iso or 0-1 VDC negative ground

 

Alarm:

Dual Alarm Relay

 

Mounting:

General Purpose

 

Operating Temperature:

5-45oC (41-113oF)

 

Sample Temperature:

5-45oC (41-113oF)

 

Accuracy:

±2% of full scale at constant temperature

 

Linearity:

±2% of full scale

 

Repeatability:

±1% of full scale

 

Drift:

±1% of full scale per week at constant tem-

 

 

perature

 

Response Time:

90% of full scale in less than 5 seconds

 

Span Stability:

Less than ±1% of full scale change per month

 

Noise:

±1% of full scale

 

Classification:

7300: Explosion proof, suitable for Class I,

 

 

Div 1, Groups B, C, & D

 

 

7310: General purpose

 

 

 