90OPTIONAL PARTS
CABLETIE
REMOTE
CONTROLCABLE
REMOTECONTROL CABLE
REMOTECONTROL BOX
MAINTENANCECOVER GROMMET
PLUG
Pass the remote control cable through the supplied wireg rommet
and fit the grommet intothe maintenance cover knockout.
Plug the remote control cable into the 6-pin connector.
Install the maintenance cover and tighten the coverscrew.
To avoid accidentally unplugging the remote control cable, secure
the cable to the generator frame witha cable tie as shown.
When the remote control is not
being used, replace the plug on the
connector.
Never operate the generator
without the maintenance cover in
place, as poor engine and generator
performance will result.
7.
4.
5.
6.
07/03/13 16:34:55 31Z11600_091