GA-3.6H Series— GENERATOR OPERATION/SHUTDOWN

5.Read the voltmeter on the front panel of the generator (Figure 20) and verify that 240 VAC is present at the 240V twist-lock receptacle. Using an external voltmeter verify that 120V is present at the 120V twist-lock and GFCI duplex receptacles.

Figure 20. 60 Hz Output Receptacles

Stopping the Engine

1.Place the main circuit breaker (Figure 21) in the OFF position.

Figure 21. Main Circuit Breakers (Off)

2.Place the idle control switch (Figure 22) in the OFF position.

Figure 22. Idle Control Switch (Off)

3.Let the engine run at idle with no load for 2-3 minutes.

4.To shut-down the engine, place the generator's operation switch (Figure 23) in the OFF position.

When the full power switch is in the 240

NOTE volt (down) position, you can take up to half of the rated power of the generating set at 120 volts from the GFCI duplex

receptacle and up to half of the rated power of the set at 120 volts from the 120V twist-lock receptacle; or full rated power of the genset at 240 volts from the 240V twist-lock receptacle.

Figure 23. Generator Operation Switch (Off)

5.Place the engine fuel valve lever (Figure 24) to the "OFF" position.

When using a combination of dual

NOTE receptacles, total load should not exceed the rated capacity of the generator.

Connecting the Load

1.If small wattage power tools are required, connect them to the 60 Hz output receptacles at this time.

Figure 24. Engine Fuel Valve Lever (OFF Position)

6. Remove all loads from the generator.

GA-3.6H SERIES A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (11/01/05) — PAGE 25

Page 25
Image 25