GA-3.6H Series— PREPARATION FOR LONGTERM STORAGE

Generators Storage

For storage of the generating set for over 30 days, the following is required:

Drain the fuel tank completely, or add STA-BIL to the fuel.

Run the engine until the gasoline in the carburetor is completely consumed.

Completely drain the oil from the crankcase and refill with fresh oil.

Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the cylinder and crank slowly to distribute the oil.

Slowly rotate the engine a few times with the starter Rope and install a new plug.

Pull out the starter rope slowly and stop at the compression point.

Clean all external parts of the generating set with a cloth.

Cover the generating set and store in a clean, dry place.