GA-3.6H Series— CONTROLS AND INDICATORS

Model GA3.6HZ shown. Location of Full

NOTE Power Switch for Models GA3.6H and

GA-3.6HA, is on front control panel.

Figure 2B. Generators Components

11. Full Power Switch – The generators are provided with a full power switch. Figures 2C and 2D show simplified wiring diagrams of the dual voltage system.

When the full power switch is in the 120 volt (up) position, you can access the full rated power of the generators at 120 volts from the GFCI duplex receptacle and the120V twist-lock receptacle, or a combination of both receptacles as long as the total load does not exceed the generating set capacity.

Figure 3C. 120V Full Power Switch Simplified Diagram (Up Position)

When the full power switch is in the

NOTE 120V position, the 240V twist-lock receptacle cannot be used.

When the switch is in the 240 volt (down) position, you can acess half of the rated power of the generating set at 120 volts from the GFCI duplex receptacle and up to half of the rated power of the set at 120 volts from 120V twist-lock receptacle; or full rated power of the set at 240 volts from the 240V twist-lock receptacle.

Figure 3D. 120/240V Full Power Switch Simplified Diagram (Down Position)

12. 120V Output Receptacle – NEMA L6-20Rtwist-lock receptacle will provide 240V, 20 amps, 60 Hz.GA-3.6HZ only.

13. GFCI Ground – This ground connection point should be connected to a good earth ground (ground rod). Applies

to GA3.6HZ only.