When Check Character is set to Validate and Transmit, the scanner will only read Code 11 bar codes printed with the specified type check charac-
ter(s), and will transmit the character(s) at the end of the scanned data.
Validate and Transmit OneCheck DigitValidate and Transmit TwoCheck DigitsValidate and Transmit AutoSelect Check DigitsCode 11 RedundancyIf you are encountering errors when reading Code 11 bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 11 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.
Code 11 Redundancy6 - 21