iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide

iGSM Communications Module Information

ON – NOT registered with AlarmNet.

GRN

OFF – Registered with AlarmNet.

 

 

 

FAST BLINK – Download session with Compass

 

 

 

in progress.

 

 

 

SLOW BLINK – In unison with yellow LED,

 

 

 

registration in progress.

 

 

 

 

 

 

 

ON – Message transmission pending.

YEL

QUICK PERIODIC BLINK – Normal.

 

 

 

 

 

 

FAST BLINK – Message waiting for network ACK.

 

 

 

SLOW BLINK – Idle power abnormal.

 

 

 

SLOW BLINK – In unison with green LED,

 

 

 

registratration in progress.

 

 

 

 

 

 

 

ON – No contact with network.

RED

OFF – Normal.

 

 

 

 

 

 

SLOW BLINK – Loss of communication with the

 

 

 

Dialer Capture Module (ECP fault).

 

 

 

FAST BLINK – No network contact AND loss of communi-

 

 

 

cation with the Dialer Capture Module.

 

 

 

Note: If all LEDs FAST BLINK in unison with

the RSSI LEDs this indicates a Hardware Error.

7720P

PRIMARY POWER: 9 - 16.5 VAC

 

CURRENT: 900mA PEAK, 70mA STANDBY

 

BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP

Programmer

 

 

 

Port

FCC:XXXXXXXXXX

IC: YYYYYYYYYY

 

 

 

TB 1

 

 

 

1

 

 

 

2

 

 

RSSI / Mode

3

 

 

and

4

 

GPRS M1 M0 RSSI

status LEDs

5

 

IBS

6

Tamper

 

 

7

 

 

Switch

 

Mode

8

 

 

 

Switch

9

 

 

 

 

 

10

 

 

 

11

 

 

 

BLINKING – Network collision detected.

Network Collision

 

 

OFF – Normal.

YELLOW

 

 

 

 

 

 

ON – 100 MB/S link to Internet.

Link Speed

 

 

OFF – 10 MB/S link to Internet.

GREEN

 

 

 

 

 

 

ON – Ethernet Link detected.

Ethernet Link/Activity

 

 

OFF – No link detected.

 

 

GREEN

 

 

 

 

FAST BLINK – Transmitting/Receiving Data.

 

 

 

 

 

 

 

 

 

iPGSM-COM-002-V0

MODULE'S RECEIVED SIGNAL STRENGTH (RSSI)

When the Mode Switch is NOT depressed, LED 1 will illuminate red.

The remaining LEDs indicate RSSI (Received Signal Strength).

MODULE'S OPERATION MODE

When the Mode Switch IS depressed, LED 1 will be OFF.

LEDs 2 and 3 indicate the module's communication mode with the Dialer Capture Module.

 

Mode

LED 2 (yellow)

LED 3 (yellow)

 

 

 

 

 

 

 

ECP

OFF

OFF

 

 

 

 

 

 

Zone (NOT USED)

ON

OFF

 

 

4204 (NOT USED)

OFF

ON

 

 

 

 

 

 

2 - 4204 (NOT USED)

ON

ON

 

 

 

 

 

MODULE'S STATUS

When the Mode Switch IS depressed, LED 1 will be OFF.

LEDs 4, 5, and 6 indicate the module's Status.

LED 4 (green)

LED 5 (green)

LED 6 (green)

 

 

 

ON - Connected to

ON - GPRS service

ON - Module registered, no second

Internet.

available.

site available.

 

 

 

OFF - Not connected

OFF - No GPRS service

OFF - Module not registered with

to Internet.

available

network carrier.

 

FAST BLINK - GPRS in

SLOW BLINK - Module registered, second

 

use.

site available, and low signal strength.

 

 

NORMAL BLINK - Module registered, second

 

 

site available, acceptable signal strength.

 

 

FAST BLINK - Module registered, second

 

 

site available, excellent signal strength.

10

Page 12
Image 12
Honeywell 800-04433V1 manual IGSM Communications Module Information, OFF Normal Slow Blink Loss of communication with

800-04433V1 specifications

The Honeywell 800-04433V1 is a robust and efficient product designed to enhance the operational capabilities of various systems. As part of Honeywell's extensive portfolio, this device is engineered with advanced technologies that cater to both industrial and commercial applications, emphasizing reliability and user-friendly operation.

One of the standout features of the Honeywell 800-04433V1 is its versatility. It is compatible with a wide range of systems, making it an ideal choice for facilities looking to upgrade their operations without overhauling existing infrastructure. The device supports several communication protocols, ensuring seamless integration into various control architectures.

The Honeywell 800-04433V1 is built with advanced sensing technologies that provide accurate data readings and measurements. This high level of precision is crucial for applications requiring stringent compliance with safety and performance standards. Its robust sensors are capable of operating under challenging environmental conditions, ensuring consistent performance regardless of external factors.

Energy efficiency is another prominent characteristic of the Honeywell 800-04433V1. The device is designed to minimize power consumption while maintaining optimal operational performance. This not only helps businesses reduce operational costs but also contributes to a smaller carbon footprint, making it a sustainable choice for modern enterprises.

The user interface of the Honeywell 800-04433V1 is intuitive and easy to navigate, allowing operators to monitor and control processes with minimal training. The device typically features a clear display and programmable settings, enabling users to customize operations according to specific needs and preferences. This ease of use translates into increased productivity and more streamlined workflows.

In terms of durability, the Honeywell 800-04433V1 is constructed with high-quality materials that can withstand the rigors of industrial environments. Its design often incorporates protective features such as moisture resistance and shock absorption, which extend the device's lifespan and reduce the potential for maintenance and replacement costs.

Moreover, Honeywell prioritizes innovation, and the 800-04433V1 reflects this commitment through its ongoing support and software updates. This ensures that users can benefit from the latest advancements in technology, further enhancing their operational capabilities.

In summary, the Honeywell 800-04433V1 is an advanced device designed for efficiency, flexibility, and durability. With its intuitive user interface, energy-saving characteristics, and compatibility with various systems, it stands out as a top choice for businesses looking to enhance their operational effectiveness.