STEP 1. PREPARE FOR INSTALLATION

Check Table 1, the compatibility chart, to make sure the thermostat is compatible with your system. If your system is not compatible, call Honeywell Customer Relations Center, toll-free, 1-800-468-1502.

Table 1. Compatibility Chart.

 

 

System Type

Compatibility with CT3500/CT3595

Gas — Standing Pilot

Yes

 

 

Gas — Electronic Ignition

Yes

 

 

Gas-fired Boilers

Yesa

Gas — 750 Millivolt Heat onlyb

Yes

Oil-Fired Boilers

Yesa

Oil-Fired Furnace

Yes

 

 

Electric Furnace

Yes

 

 

Electric Air Conditioning

Yes

 

 

Baseboard Electric (120/240 line volt)c

No

Single Stage Heat Pump

Yes

 

 

Multistage Heat Pumps/Multistage Equipment

No

 

 

aCompatible with 2-wire Honeywell and Taco zone valves. Not compatible with 3-wire zone valves or 2-wire White Rodgers no. 1361 zone valves.

bMillivolt system must be heating only.

cNot compatible with any 120/240 volt system.

Package Contents

Thermostat

Wallplate

Screws and anchors

Wiring labels

3 Energizer® AA batteries

Owners manual

Tools Required

Screwdriver

Drill