The neon light on the air cleaner doesn’t come on

The neon light on the air cleaner doesn’t come on

The WASH LED on the W8600E comes on

The CHECK LED on the W8600E comes on

You smell ozone and find it objectionable

1.Make sure the furnace or air conditioner blower is running.

2.On models without the Solid State Performance Indicator, if the electronic cells are wet, check again in 2 to 3 hours.

3.Make sure the appropriate fuse or circuit breaker is ok.

1.Cell and prefilter washing is past due; wash as soon as possible.

2.Make sure cell(s) are correctly installed in air cleaner.

3.Wipe ionizer wires to remove deposits. NOTE: Use the wash reminder schedule to establish a washing schedule that prevents the WASH LED from coming on.

1.Make sure cell(s) are clean and dry.

2.Check cell(s) for visible damage.

Call your heating and air conditioning dealer.