☞It is impossible to use BMB and SENS functions simultaneously !!!
To use BMB or SENS, select “BMB/SENS” switch one of two,
To use neither BMB nor SENS, select “BMB” and level “H1,H0” to OFF. or select “SENS” and set the Rotary switch “7” to “0”.
◆SENS( Sensitivity Up mode ) Mode
If the sensitivity ON mode is selected and in low light conditions, the camera sensitivity is increased by getting picture from the memory.
Maximum sensitivity is selectable out of 9 steps . ( Refer to Fig5 )
BMB | 0 1 |
9 | |
8 | 2 |
7 6 5 4 3 |
SENS | “7” FIELD switch |
|
15
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Mode | Setting | Fields/sec |
| Remark |
| ||
|
| 0 | OFF | 60 |
|
|
|
|
|
|
| 1 | X2 | 30 |
|
|
|
|
|
|
| 2 | X4 | 15 |
|
|
|
|
|
|
| 3 | X6 | 10 |
|
|
|
| 16 |
|
| 4 | X8 | 7.5 |
|
|
|
| |
| 5 | X10 | 6 |
|
|
|
|
| |
|
| 6 | X16 | 3.8 |
|
|
|
|
|
|
| 7 | X32 | 1.9 |
|
|
|
|
|
|
| 8 | X64 | 0.9 |
|
|
|
|
|
|
| 9 | X128 | 0.5 |
| Default |
|
|
|
|
| Fig 5. Maximum sensitivity setting table |
|
|
|
| |||
| ☞ In the sensitivity ON mode , sensitivity is automatically controlled within maximum | ||||||||
| sensitivity setting value. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|