CHECKING YOUR HUMIDIFIER OPERATION

HE360A POWERED FLOW-THROUGH HUMIDIFIER

CHECKING YOUR HUMIDIFIER OPERATION

After winter startup or servicing, use the following steps to check the humidifier operation:

1.Turn on the humidifier power and water supply.

2.Turn the humidity control to its highest setting and set the thermostat to 10°F (6°C) above the room temperature.

3.Observe that water is flowing out of the drain hose.

NOTE: The furnace blower must be running to activate the humidifier.

4.Reset the thermostat and humidity control to a comfortable setting for automatic operation.

TROUBLESHOOTING YOUR HUMIDIFIER

Problem

What to Look For

What to Do

Low

Furnace blower

Reset circuit breaker or check for blown fuse.

humidity

not operating.

Check that the furnace power is on.

 

 

Check all external wiring connections.

 

 

Check the humidity control setting.

 

 

Call a professional heating contractor.

 

Rapid air changes.

Keep doors and windows closed.

 

Drafts (cold air is

Close fireplace damper when not in use.

 

dry and is an

Keep exhaust fan running time to a minimum.

 

added load to the

Seal around doors and windows.

 

humidifier).

 

High

Condensation on

Turn off humidity control and water until

humidity

walls.

condensation is completely evaporated.

 

Heavy

Turn humidity control down low enough to

 

condensation on

eliminate condensation caused by moisture from

 

windows.

bathing, mopping, cooking, etc. If moisture

 

 

persists, more ventilation is needed.